2016年11月3日星期四

Pipeline pump installation method

1, the equipment shaft radial runout should be ≤ 0.04 mm, the axial movement is not allowed to more than 0.1 mm;
2, the sealing parts of the device should be installed to keep clean, sealed parts should be cleaned, sealed face intact, to prevent impurities and dust into the sealing area;
3, in the installation process is strictly prohibited bumps, beating, so as not to pay the mechanical seal friction failure and seal failure;
4, when installed in contact with the sealing surface should be coated with a layer of clean mechanical oil, so that can be successfully installed;
5, the installation static ring gland, tighten the screws must be uniform force to ensure that the static ring face and the axis of the vertical line requirements;
6, after installation to promote moving ring by hand, can move the ring on the axis of flexible movement, and a certain flexibility;
7, after the installation of hand drive shaft, the shaft should be no light and heavy feeling;
8, the device must be filled with media before operation to prevent dry friction seal failure;

Analysis of Pipeline Pump Parts

1, the motor: the electrical energy into mechanical energy of the main components.
2, pump seat: the pump is the main body, play a role in supporting the fixed.
3, the impeller: the core part of the centrifugal pump, it is high speed, great output, the impeller blade plays a major role in the impeller assembly through static balance before the experiment. The inner and outer surfaces of the impeller are required to be smooth to reduce the friction loss of the water flow.
Classification of Impellers
Open impeller: for conveying the material containing a large number of suspended solids, the efficiency is low, the liquid pressure is not high.
Semi-closed impeller: suitable for conveying easy to precipitate or contain solid particles, fibers and other particles of suspended particles, the efficiency is low.
Closed impeller: suitable for conveying clean liquid without impurities, high efficiency.
4, the pump shaft: motor connected, it is the transmission of mechanical energy of the main components.
5, mechanical seal: to keep the slide and the formation of the relative slip to prevent leakage of the device.

Main point of use of pipeline pump

1, the test work: Check whether the loose connections; hand-drive coupling to make the rotor a few turns, to see whether the unit is flexible rotation, whether the sound and the severity of uneven feel to determine whether the pump foreign body or shaft Bending, sealing the installation is not correct, etc .; check the sealing cavity of the cleaning oil on the 20th whether the filling 1/2 cavity space; pump unit surface is clean; unit turned to no-load test.
2, manual start: Pump (first), slightly open the outlet valve, start the motor, the pressure rise and confirm the smooth operation of the pump group gradually open outlet valve to the working condition requirements.
3, operation check: pipeline pump in the normal operation of the frequency, should regularly check and record the pump group ammeter, voltmeter, import and export vacuum gauge, pressure gauges and flow meters and other instrument readings, unit vibration, noise, temperature Is normal, the shaft seal should not have obvious fuel oil leakage.
4, normal parking: Close the discharge valve, the pump light load, stop the motor.
Emergency stop status:
⑴ pump motor operating ammeter indicates abnormal (too large or become very small); pump system is not the normal sound.
⑵ vacuum pump inlet pressure gauge, outlet pressure gauge indicates abnormal pump vibration and issued a different sound, a serious decline in performance.
⑶ pump motor odor, shaft seal leakage at the aviation fuel, bearing temperature more than 75 degrees and so on.

2016年10月30日星期日

Vacuum pump exhaust oil how to solve?

Vacuum pump after use for a long time, if not for regular maintenance would be a big or small issues, such as exhaust oil, vent oil is only one: the main reasons why exhaust filters.
First, the causes of exhaust filter oil
1, exhaust filter fails, the oil and gas can't completely separate.
2, exhaust filter installation bad mouth o-ring seal.
3, exhaust filter installation does not reach the designated position. Shaft seal leakage, leakage problem is common.
Found that the shaft seal leakage due to abrasion, oil, must want to change the shaft sealing ring. Different pump types, different manufacturers design of shaft seal structure is not the same. According to the original design pattern with similar or identical seal change. Standard parts such as spring rubber ring wear air leakage is not serious, detachable go a few rounds of fastening wire spring loaded again can. Serious wear and tear shall be in accordance with the original diameter changing new sealing ring. O, j type and Jo type sealing ring, all have standard series, location should be paid attention to when assembling trued and pressure. Some of the rubber sealing ring can be homemade. Its inner diameter can be obtained by measuring the shaft and the shaft hole, size should be slightly smaller, there should be room for compaction thickness, easy to mount can lock itself.
Second, the vacuum pump daily maintenance methods
1, 3 to 6 months will be in a special vacuum pump oil, each pump in the factory when will indicate what is oil. You want to change original, don't mix,
2, about six months in a vent filters and in filter and treasure to vacuum pump oil.

Introduction to feed water pump running in the process of common failures and solutions

With the constant progress of the society, electric power and industrial development and people's life is closely related to the high grade energy, one of the growing demand for its people. Thermal power though right now the consumption of fossil fuels such as coal and pollution of the environment has a great influence, but according to the special national conditions of our country, coal is still the main mode of power supply, the proportion of the total installed capacity at about 70%. Thermal power plant is composed of boiler, steam turbine and generator three host and feed water pump, coal mill and other auxiliary equipment and control system. Feed water pump is a core system of thermal power plant boiler auxiliaries, its purpose is to continuously provide to boiler has the pressure, temperature and flow rate of water supply. Feed water pump is generally divided into two kinds of electric and steam, shanxi jincheng a 300 MW thermal power plant boiler supporting electric feed water pump. In the plant electric feed water pump, for example, this paper introduces the working process of the feed water pump, the common faults in the operation process and the corresponding solutions, in order to provide some reference for the general electric power staff.
Feed water pump is not only to provide sufficient pressure, temperature and flow rate of feed water boiler, but also provide reheater, superheater attemperator and reduction of warm water, so the safety and reliability of the feed water pump, a direct impact on the safety operation of boiler system and steam turbine generator set, serious when still can cause boiler water dry the occurrence of serious accidents, such as the higher the greater unit capacity and parameter, the importance of the feed water pump, the more prominent. [1]
Shanxi jincheng a thermal power plant 300 MW unit configuration is as follows: 50% capacity electric three main feed pump, two with one case. Models for DG600-240 - v (FK6D32); Type of cylinder core package, horizontal; Has six levels of impeller, motor models for YKS800-4 electric (Shanghai), feed water pump directly driven by motor through coupling, booster pump driven by motor directly, feed water pump and coupling, coupling and motor and motor and booster pump through the fold type shaft coupling.
Two common faults in the operation of feed water pump
Feed water pump can be stable operation of the safety and economy of boiler has a close relationship with large boiler unit generally configuration many sets of feed water pump, there are one or two electric feed water pump as backup. The power plant capacity 50% electric three main feed pump, 2 in one case, in the process of actual operation, the feed water pump fault has common motor overheating overheating [2], the pump body, pump body flow and system fault, such as vibration malfunction phenomenon, the possible reasons and solutions to see table 1.
3 in the operation of the feed water pump fault solution
3.1 the feed water pump troubleshooting
3.1.1 mechanical seal leakage, high temperature in the water injection pipe
As water injection pipe in air, check the mesh cleanliness, check whether the external cooling water is enough; If big is the collapse of the mechanical seal leakage, check whether the pump ring is installed backwards, cooler and the purity of the mesh, dynamic and static ring for wear.
3.1.2 bearing temperature is high
Check the lube oil cooler, increase the cooling water, adjust the oil hole plate, increase in traffic; Adjust the pressure relief valve, the oil pressure; The collapse of the bearing when necessary, check the bearing clearance.
3.2 the feed water pump booster pump troubleshooting
3.2.1 mechanical seal leakage
Spring force is not enough, loosen screw mechanical seal on the shaft sleeve, the sleeve to move about 1 ~ 2 mm, outside the pump to tighten the screw. If the big leakage, the need to strip inspection, replace if necessary.
3.2.2 the drive end bearing oil
Thrust bearing oil return is not the driving end plug holes on the bearing cover plate, often to the bearing chamber oil return, because of the large amount of oil return cause oil leakage. Reveal a plug hole plate, narrow small aperture.
3.2.3 booster pump shaft in small flow up
Double-suction volute pump in the small flow rate, the impeller out of the mouth room is easy to produce pressure fluctuations caused by axial channeling move, in the big traffic (about 300 t/h or above) or disappear completely, cold center, in accordance with requirements can reduce the booster pump shaft move.
3.2.4 cold installation to the center
Remove the upper cover of motor bearing, with a precise level 4 meters, on the shaft neck area, check the shaft back in internal carotid should be equal on both sides of the shaft, and in the opposite direction. If you need adjustable wedgeplug pad under the floor, to ensure our internal jugular back degrees equal on both sides of the axis, the reset bearing upper cover.
3.2.5 the axial position of motor rotor must be consistent with the center of the magnetic field of the motor
Runtime box body heat expansion, gear tooth force when rotating, bearing clearance, and the hydrodynamic lubricating oil can cause axis offset. Therefore in the pump set is cold find center, must be set in the horizontal, vertical, axial offset, the expected offset compensation when starting and running.
4 conclusion
Thermal power is made up of boiler, turbine and generator three host and feed water pump, coal mill, such as auxiliary coordination of unified whole, an equipment or system malfunction could affect the safety and reliability of the whole system, especially the feed water pump as the working medium for boiler equipment, is the core of the auxiliary boiler system, its role in the boiler system is self-evident. In the process of actual operation, because of the feed water pump working environment is bad. Frequently, all kinds of feed water pump failure, the staff must be regularly for feed water pump of power plants for maintenance, found problems in a timely manner, to ensure the safe operation of boiler feed water pump and system.

The working principle of the vertical self-priming pump

Self-priming pump is southern commonly used a pump. Principle is to use the water velocity of flow momentum, drives the pump impeller impeller pumping water into the river. Thrown into the river to the pump pumping, but must be water, or a place to have head.
Self-priming pump and centrifugal pump is different in general. Centrifugal pump, before work, pump body and feed line must be tank filled with water into a vacuum, when the fast rotating impeller blade promote water quickly spin, spin the water under the action of centrifugal force, fly away from the impeller, pump in the water is thrown, the center of the impeller part form the vacuum area. Water in the original water at atmospheric pressure (or hydraulic) through the pipe network pressure under the action of the feed water pipe. So circulates, can achieve continuous pumping.
Self-priming pump is not need irrigation water diversion, this is the origin of self-priming pump.
Self-priming pump self-priming principle: as the pump shell's special design. Its high sealing performance than general centrifugal pump, and motor to halt the water in the pump housing will not automatically after emptying, motor drive the turbine at high speed, quickly make form a negative pressure (vacuum) inside the pump. After using atmospheric pressure pumping water to the pump shell, centrifugal head again. So, self-priming pump suction, no more than an atmospheric pressure, about 11 m.
Scope of application of self-priming pump
1, suitable for urban environmental protection, construction, fire control, chemical, pharmaceutical, dyes, and dyeing, brewing, electric power, electroplating, paper making, washing of industrial mines, cooling of equipment, etc.
2, with a swing arm sprayer, the water can rush into the air, a small drips to spray, is a good tool for farm, nursery, garden, garden.
3, suitable Yu Qingshui, water, chemical liquid medium with acid, alkalinity and with general mushy slurry (medium viscosity < 100 mm pearl, solid content of 30%).
4, and can be matched with pressure filter of any model and specifications, send paste to filter machine supporting the ideal pump for filter.

The choice of drainage pumps and requirements

Building use drainage pumps are submersible sewage pump, liquid discharge pump, vertical sewage pump and horizontal sewage pump, etc. Because within the building area is lesser, general displacement is not big, give priority to use diving sewage pump and drainage pump liquid discharge pumps, including submerged sewage pump is in commonly used in important places; Vertical and horizontal sewage pumps pump set isolation requirements, since the irrigation water, and take up a certain field, so the less use in the building.
Drainage pump flow should be according to the second life drainage design flow of the selected; When a displacement adjustment, drainage maximum hours flow selected according to life. Fire elevator collecting basin drainage pump flow within not less than 10 l/s.
Drainage pump lift according to hoisting height, piping loss calculation is determined, then add some free head. Free head should be 0.02 ~ 0.03 MPa. Drainage pump suction pipe and outlet pipe flow velocity should not be less than 0.7 m/s, and should not be more than 2.0 m/s.
Public buildings should be in each life drain collecting basin as a unit set up a backup pump, at ordinary times should be interactive operation. Basement, equipment room, garage flushing the drainage of the ground, such as when there are more than two and two drainage pumps don't pump equipment. When collecting basin can't set accident drainage pipe, water pump should be uninterrupted power supply; When can close drainage inlet pipe, not for uninterruptible power supply, but should be set up alarm device.
As ascension with larger impurities of sewage, waste water, the different set inside the pool diving sewage pump outlet pipe should not be combined discharge; When raising the waste water, according to actual situation consider different collection pool diving sewage pump outlet pipe combined discharge.
Two or more than two Shared a water pump outlet pipe, shall be installed on each pump outlet pipe valve and check valve. Single pump drainage could produce flow backward, should set the check valve. Don't allow pressure drainage clearance and architecture in gravity drainage consolidation.
When diving sewage pump ascending containing large pieces of debris, appropriate of diving sewage pump with a crushing device; When ascending contains more fiber content of sewage, appropriate USES thoroughfare diving sewage pump.
When diving sewage pump motor power is greater than or equal to 7.5 kW or outlet pipe diameter greater than or equal to the DN100, water pump fixed automatic coupling device can be used; When diving sewage pump motor power is less than 7.5 kW or outlet diameter less than DN100, can install a hose mobile. Wastewater collection pool with diving sewage pump drainage, should set the pump fixed automatic coupling device, convenient pump maintenance.
Drainage pump should be able to automatic start-stop and field manual start-stop. Pumps can run in parallel alternating more, also can be segmented in operation.