2016年11月3日星期四

Pipeline pump manufacturers to talk about how to adjust the pipeline pump flow

When using the pipeline pump will encounter the need to adjust the flow of time, the following by our pipeline pump manufacturers in Shanghai Weihu pump for everyone to talk about what methods to adjust the pipeline pump flow.
 
 
    When this method is used to regulate the flow rate, the required power can be reduced to a minimum, and an overheating in the flow regulation process can be eliminated. Steam turbines and internal combustion engines easily adapt to speed regulation at very little additional cost. A variety of mechanical, magnetic, hydraulic transmission and DC and AC variable speed motors can be used to adjust the speed. In general, variable speed motors are too expensive and can only be adjusted with adjustable blades only after economic studies have been done for special cases.
 
    Second, bypass regulation
 
    All or part of the flow may be diverted from the discharge line of the pipeline pump through the bypass line to the suction port of the pump or other appropriate point. The bypass can be equipped with one or more flow orifice plates and a suitable control valve. Metering bypass is usually used to reduce the boiler feed pump flow, mainly to prevent overheating. Substantial power savings can be achieved by bypassing the surplus flow of the propeller pump to replace the outlet throttling.
 
    Third, exports throttle
 
    This is one of the most common and inexpensive flow adjustment methods for low- and medium-specific speed pumps. Usually this method is also limited to low, medium speed than the number of pumps used. Partially closing any type of valve on the outlet line will increase the system head so that the system head curve will intersect the pipe pump head curve at a lower flow rate. The outlet throttling moves the operating point to a lower efficiency point and has a power loss at the throttle valve. This may be important for large-scale pump installations, and a higher investment adjustment method may be more economically attractive. Throttle to the dead point may cause fluid overheating in the pump, bypass can be used to maintain the necessary minimum flow, or a different adjustment means. This is very important for the pumps mentioned above for the treatment of hot or volatile liquids.
 
    Fourth, the intake throttling
 
    If there is sufficient NPSH available, then the suction line can be throttled by saving some power. Because the throttling of the outlet can cause the liquid to overheat or vaporize, the jet fuel pump often uses inlet throttling. At very low flow, the impeller of these pumps is only partially filled with liquid, so the input power and temperature rise is about throttle exhaust throttle full operation bit 1/30 condensate pump flow is usually used to control the depth of submergence 7, This is equivalent to the entrance throttling. Special designs can reduce the cavitation damage of these pumps to a negligible extent, but the energy levels also become quite low.
 
    Fifth, qi
 
    Air intake to the suction line of the pump is also a method of regulating the flow rate, this method can save some power compared with the output throttle. In general, it is not desirable to have air present in the delivered liquid and too much air always has the risk of the pump losing its priming head, so this method is rarely used in practice except in a few cases.
 
    If you want to buy pipeline pump can contact us  Weihu pump, our company is specialized in various types of pump manufacturing and computer control of water supply and drainage complete sets of equipment manufacturers to operate the pump-based products related to general motors, pumps and other related accessories.

Sewage pump should be how to go with the cable wires

When we use the sewage pump, sewage pump should be how to layout, also we need to pay attention to how to match the cable, the following is by Shanghai mine sewage pump manufacturer is simple to share with everyone, can be a reference for everyone.
First let's talk about sewage pump cable: when the installation of various types, will have the power and sewage pump machine distance is too long, need above the basis of the sewage pump accessory cable extension cable, so the size of all kinds of sewage pump power cable are decided according to the length of the cable.
Let's go ahead with sewage pump should be how to match the cable
First, to select the wiring sewage pump first according to the size of the cable to determine the length of the wiring, such as original pump configuration cable is 3 x10 cable with 100 square meters at this time should increase cable configuration 3 x16 square is appropriate. If use sewage pump itself power supply voltage is slightly lower than the voltage required sewage pump, and add the required length of cable configuration and longer, the operation of the sewage pump cable becomes larger, if the sewage pump working long hours for sewage pump motor is very bad, this kind of sewage pump under the condition of cable wiring should match YCW type or YC type rubber set soft cable, such as not cable advice to choose YCW dived into the water.
Second, if it is diving sewage pump have to according to the sewage pump conveying liquid medium to choose to match the line, such as transmission fluid is corrosive, so the outside of the cable rubber parts to choose stainless steel submersible pumps and corrosion submersible cable, or it will because the submersible cable corrosion and leakage of dangerous accidents.

Pipeline centrifugal pump in the use course of attention which points

When we use the pipeline centrifugal pump, how should we do it? Also need to pay attention to what the problem? The following by the weihu pump to share with you in the pipeline pump process we need to pay attention to those issues:
    First, pipeline centrifugal pump in the course of operation, the bearing temperature can not exceed the ambient temperature 3 ℃, high temperature shall not exceed 80 ℃.
    Second, unscrew the pipeline pump body of the water plug, irrigation diversion (or cited pulp).
    Third, start the pipeline centrifugal pump motor, when the normal operation of the pipeline pump, open the outlet pressure gauge and import vacuum pump, depending on the display of appropriate pressure, and gradually open the gate valve, and check the motor load.
    Fourth, to the pipeline centrifugal pump bearing body lubricating oil by adding bearings to observe the oil level should be at the center of the oil standard, the oil should be replaced or added.
    Fifth, close the centrifugal pump and pipeline centrifugal pump outlet pipe valve and outlet pressure gauge and import vacuum table. Jog the pipeline pump motor, see whether the motor steering is correct.
    Sixth, try to control the pipeline pump flow and head in the range indicated on the plate to ensure that the pipeline pump in the highest efficiency point of operation in order to obtain the greatest energy saving effect.
     Seventh, if there is abnormal sound pipe pump should immediately stop to check the cause.
    Eighth, the pipeline pump and pipeline from the main pump to stop using, first close the gate valve, pressure gauge, and then stop the motor.
    Ninth, check the pipeline pump and pipe and the junction with or without loosening. Turn the pipe pump by hand to see if the piping pump is flexible.
    Tenth, regularly check the pipeline pump sleeve wear, wear should be replaced after a large.
    Twelfth, pipeline centrifugal pump used in the winter season, after parking, the need to pump the lower part of the water plug screw open the media release the net to prevent cracking.
    Thirteenth, the pipeline pump long-term outage, need to open all the pipeline pump, dry water, the rotating parts and joints coated with grease installed, and properly preserved.
    Fourteenth, the pipeline pump in the first month of work, after 100 hours to replace the oil, after each 500 hours, oil change time.

Vertical pipeline pump use

ISG type pipeline centrifugal pump for conveying water and other physical and chemical properties similar to the use of water for industrial and urban water supply and drainage, high-rise building pressurized water, garden irrigation, fire booster and equipment, the use of temperature T: ≤80 ° C.
IRG (GRG) type hot water (high temperature) circulation pump is widely used in energy, metallurgy, chemical, textile, paper, hotel and other high-temperature hot water pressurized circulation and urban heating system circulation pump, IRG temperature T: ≤120 ° C, GRG Operating temperature T: ≤240 ° C.
IHG pipeline chemical pump for the transportation of non-solid particles, corrosive, viscosity similar to the liquid of water for petroleum, chemical, metallurgy, power, paper, food, pharmaceutical and synthetic fiber and other departments, the use of temperature T: 20 ° C to 120 ° C.
YG pipeline oil pump for the transportation of gasoline, diesel, kerosene and other petroleum products, the use of temperature T: -20 ° C-120 ° C.

Pipeline pump installation method

1, the equipment shaft radial runout should be ≤ 0.04 mm, the axial movement is not allowed to more than 0.1 mm;
2, the sealing parts of the device should be installed to keep clean, sealed parts should be cleaned, sealed face intact, to prevent impurities and dust into the sealing area;
3, in the installation process is strictly prohibited bumps, beating, so as not to pay the mechanical seal friction failure and seal failure;
4, when installed in contact with the sealing surface should be coated with a layer of clean mechanical oil, so that can be successfully installed;
5, the installation static ring gland, tighten the screws must be uniform force to ensure that the static ring face and the axis of the vertical line requirements;
6, after installation to promote moving ring by hand, can move the ring on the axis of flexible movement, and a certain flexibility;
7, after the installation of hand drive shaft, the shaft should be no light and heavy feeling;
8, the device must be filled with media before operation to prevent dry friction seal failure;

Analysis of Pipeline Pump Parts

1, the motor: the electrical energy into mechanical energy of the main components.
2, pump seat: the pump is the main body, play a role in supporting the fixed.
3, the impeller: the core part of the centrifugal pump, it is high speed, great output, the impeller blade plays a major role in the impeller assembly through static balance before the experiment. The inner and outer surfaces of the impeller are required to be smooth to reduce the friction loss of the water flow.
Classification of Impellers
Open impeller: for conveying the material containing a large number of suspended solids, the efficiency is low, the liquid pressure is not high.
Semi-closed impeller: suitable for conveying easy to precipitate or contain solid particles, fibers and other particles of suspended particles, the efficiency is low.
Closed impeller: suitable for conveying clean liquid without impurities, high efficiency.
4, the pump shaft: motor connected, it is the transmission of mechanical energy of the main components.
5, mechanical seal: to keep the slide and the formation of the relative slip to prevent leakage of the device.

Main point of use of pipeline pump

1, the test work: Check whether the loose connections; hand-drive coupling to make the rotor a few turns, to see whether the unit is flexible rotation, whether the sound and the severity of uneven feel to determine whether the pump foreign body or shaft Bending, sealing the installation is not correct, etc .; check the sealing cavity of the cleaning oil on the 20th whether the filling 1/2 cavity space; pump unit surface is clean; unit turned to no-load test.
2, manual start: Pump (first), slightly open the outlet valve, start the motor, the pressure rise and confirm the smooth operation of the pump group gradually open outlet valve to the working condition requirements.
3, operation check: pipeline pump in the normal operation of the frequency, should regularly check and record the pump group ammeter, voltmeter, import and export vacuum gauge, pressure gauges and flow meters and other instrument readings, unit vibration, noise, temperature Is normal, the shaft seal should not have obvious fuel oil leakage.
4, normal parking: Close the discharge valve, the pump light load, stop the motor.
Emergency stop status:
⑴ pump motor operating ammeter indicates abnormal (too large or become very small); pump system is not the normal sound.
⑵ vacuum pump inlet pressure gauge, outlet pressure gauge indicates abnormal pump vibration and issued a different sound, a serious decline in performance.
⑶ pump motor odor, shaft seal leakage at the aviation fuel, bearing temperature more than 75 degrees and so on.