2016年10月24日星期一

How to say goodbye to the sewage pump jam

Sewage pump anti-clogging performance will be more and more important? That mainly comes from two aspects: one is increase the cost of sewage disposal. Industrial companies are working to reduce water consumption per unit product production, the solid material in the sewage and fiber content is higher and higher. 2 it is used more and more sewage pump the means of energy conservation, is the speed adjusting drive mode, and the speed adjusting is cannot guarantee sewage pump will be blocked.
Aiming at the problem of frequent clogging impurities machine pump impeller, equipment operation early every wall shall be clear, air is not for the night. Although this avoids the shutdown, but often remove the pump body, cause the machine components such as pump inlet ring wear at the same time each time the air cost a lot of manpower. In order to change this situation, adding of carbon steel in the pump inlet line resistance box, and 45. Tilt Angle. Used in the filter to filter impurities again, avoid congestion. Team fouling resistance for 1 ~ 3 times a month of sewage disposal.
This scheme received certain effect, human consumption. Fouling resistance department have a vent valve at the bottom, but there is still a corner. Part of the sewage and impurities in the corner after the accumulation, in cleaning up minor gas poisoning easy cause personnel injury, is not conducive to safe operation.
Sewage pump rotor blade shape can be divided into two kinds, respectively of swirling blade and cutting blade, the blade in the form of two kinds of the most widely used. Vortex flow impeller is not in the medium to be delivered, according to the principle of fluid dynamics to boot into the pump chamber, pumping medium by pumping medium flow from the impeller. In this way, by pumping liquid medium long fiber or solid material also be pumped out together. And cutting blade, can cut up larger block solid material, which is no longer blocked.
To ensure the safe operation of the key equipment
Catalyst of metering pump is mainly used for catalyst note, prompting oligomer in polycondensation reactor, the final polycondensation reactor in polycondensation reaction. Technological requirements of polyester catalysts must note by certain proportion, and stop on time can't more than 15 rain. Otherwise will reduce the melt viscosity, product quality, etc. In order to ensure the catalyst pump running smoothly, some guarantee measures must be taken.
Replace lubricating oil and wear parts on a regular basis
Catalyst metering pump inside the main moving parts are worm, worm wheel, slider, set new piston and so on. These parts to reduce wear and tear will directly lead to pump or not, the current solution is replaced periodically lubricant, wear parts, and regular cleaning of the hydraulic chamber.
Catalyst metering pump operating rules strictly
Catalyst metering pump start and stop should be used in strict accordance with the requirements of operation. At startup, zero output open pump, to pump discharge has a certain pressure before for voltage plate filling nitrogen. Avoid diaphragm deformation is caused by the nitrogen filling, prevent diaphragm rupture; Increase the pump output to slowly; When the pump is stopped, also should slowly reduce the output of the pump.
Strengthen the maintenance of the pump
During the running of pump in the regular inspection, the key to check the oil, machine oil pump sound, outlet pressure, nitrogen gas buffer tank pressure, etc. The diaphragm of the diaphragm pump body, nitrogen gas buffer tank on a regular basis for replacement, in order to effectively prevent damage of the pump at the same time cause catalyst note the happening of the accident.

Water pump bearing maintenance method

Water pump bearing maintenance methods:
1, the new pump put into use, must be replaced after running 100 hours grease (oil), replace 1 after every run of 500 hours.
2, floating bearing is lubricated by grease, run after 1500 hours, should be replaced, grease filling the oil amount is too little or too much, because too much or too little will cause bearing grease fever, amount to general in the bearing should be 1/2 to 2/3 of the chamber volume.
3, for bearing is lubricated by lubricating oil, the oil should be added to the specified location.
4, containers of lubricating oil or grease to clean, should be sealed at ordinary times, should not have dust, iron and other sundry, in order to avoid damage to the bearings
5, motor bearings commonly used sodium base grease, the grease is characteristic of high temperature (125 ℃), but easy to dissolve in the water, so can't use it for water pump bearing lubrication.

Vertical hot water circulation pump failure reason and solution

Thermal circulation pump temperature within 120 degrees to use, installation is divided into vertical and horizontal. Hot water circulation pump failure are not lack of water, flow, noise vibration, leaking several failure to explain in detail the following various failure reason and solution.
A fault is not water, hot water circulating pump
1, import and export valve does not open, in and out of the pipeline jam, abortion impeller blocking. Solution, remove the obstruction.
Phase 2, the motor running direction is wrong, motor rotation speed is slow. Adjust the direction of motor, the motor wiring.
3, suction pipe leakage. Tighten the sealing surface, eliminate the air
4, not the filling of liquid, pump chamber in the air. Open the pump cover or open the discharge valve, exhaust air.
5, import and export of water supply is insufficient, electron absorption is high, the bottom valve is leaking. Stop check and adjust (hooked up to the water pipe and use suction easy to appear the phenomenon).
6, pipeline resistance is too large, improper centrifugal pump selection. Reduce the pipe bend, to choose the pump
Second, the heat pump fault flow insufficient reason
1, import and export valve does not open, in and out of the pipeline jam, abortion impeller blocking. Solution, remove the obstruction.
Part 2, pipelines, flow impeller blocking, scale deposition and valve opening. Remove the obstruction, readjust the valve opening.
3, low voltage. 4, the impeller wear. Change of the impeller. 5, more than the rated flow. Adjust flow down outlet valve
6, an electron is high. Reduce the suction. 7, pump bearing wear. Replace the bearing.
Three, hot water circulating pump fault vibration noise
1, pipe support. Solid line. 2, liquid mixed with gas. Improve the suction pressure and exhaust.
3, produce cavitation. Reduce the degree of vacuum. 4, bearing damage. Replace the bearing.
5, motor overload running fever. Adjust flow down outlet valve.
Four causes electrical heating, hot water circulating pump
1, the traffic is too large, the overload operation. Turn down the outlet valve
2, scratches. Check out. 3, motor bearing damage. Replace the bearing. 4, voltage is insufficient. Voltage regulator.
Five, the hot water circulation pump failure is leaking
1, mechanical seal wear. Replacement. 2, the pump body with sand holes or broken. Weld repairs or replacement.
3, sealing surface is not smooth. Trim. 4, installation bolt loosened. Tighten.

The principle of quiet water pump and the standard of options

Mute pump refers to the minimum noise of micro pumps. Micro pumps possess a into a flush and drain a mouth, and in the inlet can continue to form a vacuum or negative pressure; Larger output pressure drain; Working medium is water or liquid. An instrument of small size.
Micro pump has called "the micro liquid pump, mini pump, mini pump". Micro pump noise is not only from the motor power, and there are water and pipe wall friction noise, now some miniature pump noise is fairly small, basic can be called a mute pumps. Such as in micro self-priming pump, water dual-use WKA series, the flow in the series of CSP, and micro QZ series pump noise is very small.
What mute pumps and micro pumps in accordance with the criteria for selection? You can choose according to the following principles.
A. Working medium under normal temperature (0-50 ℃), need water or gas (water mixing or idling, dry turn), value performance, such as volume, noise, continuous use.
Description: require moisture dual-use, can turn dry for a long time, no damage to the pump; 24 hours of continuous operation; Small volume, low noise, but for flow and pressure requirements is not high.
1. With the micro pump suction or pumping air into vacuum state, but sometimes there will be a liquid water into the pump chamber.
2. Require to extraction and micro pump pumping.
3. Use the micro pump pumping, but sometimes may pump can smoke without water, in a state of "dry".
Some traditional pump fear "dry", "dry" may even damage the pump. And PHW, WKA series products is essentially a kind of compound function pump, it integrates the function of the vacuum pump and water pump, some people call it "vacuum pump. Therefore, in the absence of water, it will vacuum, there is water when it is pumped. Both in extraction condition and pumping condition, belong to the category of the normal work, and you can't have "dry" damage.
4. Main use micro pump pumping, but don't want to in front of the water by artificial add "diversion" (some pump before work need artificial add some "pilot", in this way can pump the water pumped, lower pump can't flush and even damage), namely, hope to have the self-priming pump function. Then can choose PHW, WKA series products, their strengths is that without access to water, it is vacuum, vacuum formed by pressure after the water pressure, and then began to flush

Household submersible pump energy saving techniques

Household energy saving technique of household submersible pump , sewage pump use pay attention to the point:
Household submersible pump are generally of small single-phase 220 v voltage submersible pumps, so the first thing to consider is the energy security problem, Ding Fei pump industry analysis to everyone today under the submersible pump energy saving techniques
A, in a timely manner to eliminate pipe blockage. Foreign body in inlet pipe, the impeller flow passage, or diversion shell will reduce water yield.
Second, shorten the line. Remove 1 m steel tube, 10 hours can save diesel 0.21 kg.
Three, water pump, reduce the bend. Add steering pumps inclined outfit or volute, the outlet is to sink.
Fourth, to prevent the pump inlet. Pump into the air, and water yield will be significantly reduced, to check the sealing parts maintenance.
Five, based on coupling transmission directly instead of flat belt, can improve the transmission efficiency.
Six, to expand the water pipe diameter. Change 4 meters long 10 centimeters water hose to 15 cm, 10 hours can save diesel 0.5 kg.
Seven, eliminate "anti-aircraft guns" type pipe outlet. The outlet pipe to increase energy consumption.
Eighth, in the case of water can keep clean, can remove strainer.
Nine, in mouth ring, adjust the axial clearance. Prevent impeller mouth ring and axial clearance is not appropriate, use should be adjusted according to the water pump factory.

2016年10月23日星期日

Submersible pump common faults


The use of submersible pump is a very broad, like agriculture and industry have the figure of submersible pump work, the application scope is bigger, because it has the advantage of relatively significant, but even the first-class equipment in use after a period of time, or is in use process and there will be a failure problem. In order to facilitate everyone to a more comprehensive understanding of the device, simple introduce what is common faults and the user. The leakage is the most common fault of submersible pump, is also the most dangerous factors endangering the personal safety. So when use the most afraid of is leakage, because the water in the pump body, after so long time will have the phenomenon of lower insulation resistance, the basic insulation should be played. Spring factory tell you that oil leakage is common problem. It sealed box inside the oil chamber leak, this is the main place to spill, especially when used in water, can be found to have oil stains, cleaning so in use process should pay attention to prevent oil spills.

The classification and function of the submersible pump


When we are in the use of submersible pump is sometimes encounter emergency, this time we are need to submersible pump to stop immediately, because only in this way our submersible pump will not what big problem, no matter what we in the use of machinery equipment are going to have some problems for certain, actually encounter problems are not so terrible, but we don't know what to do after have problems is the most terrible, so today we're going to tell you what to meet what problem we need to immediately after our submersible pump to stop. First we need to know is, in the use of submersible pump we found that the seamless steel tube current suddenly became high, and beyond the rated value, this time we are must of submersible pump will stop for inspection, and we found in the use of submersible pump water yield began to abnormal, for a moment out of the water for a while not out of the water, and our submersible pump in the water when the water contains impurities, this time we also need to immediately stop the pump.