2016年11月3日星期四

Shanghai pump manufacturers to talk about the structure and cooling form of centrifugal pump

In the use of centrifugal pumps, we will reduce the centrifugal pump sealing temperature to improve the efficiency and service life of centrifugal pumps, the following by our Shanghai pump manufacturers to say,
    First of all, we say that the centrifugal pump seal structure
    1, single-ended centrifugal pump seal: the use of injection-type washing, washing liquid is about 100 ℃ by the second line of wax oil, the pressure than the sealed cavity high 0.05-0.15Mpa. Gland outside the use of hot water (soft water) for rapid cooling. One cycle (ten months) can be used in general.
    2, centrifugal pump metal bellows seal: compact, easy to install, in the case of the same auxiliary system, the life of 2-3 times the normal seal.
    3, centrifugal pump double-end mechanical seal: the cycle of washing, plus external cooling, life is single-sided 1.5-2 times.
    4, centrifugal pump friction pair selection hard to hard (YG6 / YG8, SiC / SiC, etc.), high viscosity, with a small amount of solid particles of the medium or crystallization of the media, have a good effect.
    Then we talk about the centrifugal pump cooling form.
    1, domestic centrifugal pump in the sealed chamber around the cooling water jacket set to cool the water, can seal the chamber temperature is reduced to 200-250 ℃.
    2, on the single-ended seal, the use of injection-type cleaning, from the outside lead clean, the temperature of about 100 ℃ wax oil (usually without diesel, because diesel is finished), both reduce the temperature and improve the working environment is effective Approach.
    3, gland outside the use of quench water; in addition to lower temperatures, but also to prevent clogging sewer.

Submersible pump repair and maintenance

Submersible pumps on a regular basis on the submersible pump and its control system for comprehensive maintenance, at least l times a year to do a comprehensive preventive maintenance, including:
    (1) when the vibration of the sound and voltage and current with or without abnormalities; stainless steel multi-level deep well submersible pump
    (2) start the device is working properly;
    (3) whether over-temperature water leakage alarm;
    (4) whether the multi-protection established by the measurement and control is frequent;
    (5) the main cable and control cables are aging and cracking;
    (6) whether the main contactor sticky oxidation or burr;
    (7) thermal relay settings are correct;
    (8) whether the winding insulation signs of aging;
    (9) Insulation resistance to ground is too low;
    (10) three-phase winding resistance is balanced;
    (11) the stator rotor to ask whether there are sweeping or scratches;
    (12) control system level gauge is accurate;
    (13) whether the upper and lower limit output is normal and reliable;
    (14) whether the float action is reliable;
    (15) whether the temperature detection components aging malfunction;
    (16) whether the oil emulsification;
    (17) mechanical seals are intact;
    (18) bearing with or without wear;
    (19) impeller wear or cavitation;
    (20) whether the shaft rust deformation or wear;
    (21) whether the motor inside and outside fastening screw loose;
    (22) cooling jacket and circulating water pipes in the presence of debris;
    (23) whether the pump and the surrounding sediment deposition or blockage.
    In the preventive maintenance and submersible pump operation process, should be correctly distinguish between over-temperature alarm, the alarm is really over-temperature or aging components of the malfunction. In the case of component aging, the signal will only access the alarm signal, not to directly participate in control, to reduce the frequent start of the submersible pump.
    Frequently Asked Questions in Maintenance Work Submersible pumps are immersed in water for long periods of use, causing the aging of the main cable skin to crack. Water penetrates the cable directly into the submersible pump. Therefore, it is necessary to inspect the cables regularly, Cracks, cleaning the surface of the cable after cleaning, waterproof tape can be used for waterproofing, but be careful to soak a few hours after the insulation check with a shake table to meet the requirements before put into operation. Replace the main cable with an insubstantial or non-repairable value. Because the main cable is a watertight connector with a dedicated cable, the replacement price is more expensive, so the process can be used to save costs of bonding.
    In the daily inspection, in addition to full operation control, test instruments, but also to display their subjective active role, as Chinese medicine practitioners to diagnose the disease "look, smell, ask, cut" as abnormal pump abnormalities. "Look" is to see, take a look at the instructions of various ministries pressure, flow, temperature, current, voltage is normal, the pump components have deformation, discoloration, change and whether the leak, with or without plugging; Smell, smell the unusual taste, liquid hydrocarbons, gasoline, benzene and other smells of leakage, equipment, paint, rubber and other insulation burnt paste paste taste; "ask" is to listen, listen to the voice of the rolling sector, with or without Abnormal sound, such as water hammer, friction sound, percussion, vortex sound, breaking sound, etc .; "cut" is to touch, touch whether overheating, vibration and so on. Only in this way the role of the operator, in a variety of test instruments, instruments of assistance, can the daily inspection well, early detection of anomalies, preventive measures.

How to reduce the energy consumption of submersible pumps?

How to reduce the energy consumption of submersible pumps?
We all know that in the summer is the peak of water, so the pump on a good maintenance of some, began to use, then in the course of how we like to reduce the energy consumption of wells with submersible pumps?
Here we will explain in detail for you some:
First, the pump surface and pressure water chamber (also known as volute) on the surface rust.
Surface corrosion bumps will reduce the pump water 7% -8%; maintenance only steel brush and iron sandpaper or grinding wheel smooth, you can make it in the work of fuel consumption or power consumption reduced by 9% -14%.
Second, the seal ring gap increases
According to the test when the impeller radius in the direction of the gap increased by 4 mm, the pump water will be reduced by 10%; maintenance only with organic adhesive plus asbestos back to the factory-defined gap, you can make the pump fuel consumption at work or electricity Consumption reduced by 10% -12%.
Third, the pressure chamber and impeller axis does not coincide
When the pressure chamber and the impeller axis deviation of 2 mm or more than 2 degrees, the pump water will be reduced by 5% -6%; maintenance only careful measurement, carefully identify the axis coincidence of the location of the installation of a solid, you can make the pump Reduced oil or power consumption by 6% to 7% during operation.

Pipeline pump manufacturers to talk about how to adjust the pipeline pump flow

When using the pipeline pump will encounter the need to adjust the flow of time, the following by our pipeline pump manufacturers in Shanghai Weihu pump for everyone to talk about what methods to adjust the pipeline pump flow.
 
 
    When this method is used to regulate the flow rate, the required power can be reduced to a minimum, and an overheating in the flow regulation process can be eliminated. Steam turbines and internal combustion engines easily adapt to speed regulation at very little additional cost. A variety of mechanical, magnetic, hydraulic transmission and DC and AC variable speed motors can be used to adjust the speed. In general, variable speed motors are too expensive and can only be adjusted with adjustable blades only after economic studies have been done for special cases.
 
    Second, bypass regulation
 
    All or part of the flow may be diverted from the discharge line of the pipeline pump through the bypass line to the suction port of the pump or other appropriate point. The bypass can be equipped with one or more flow orifice plates and a suitable control valve. Metering bypass is usually used to reduce the boiler feed pump flow, mainly to prevent overheating. Substantial power savings can be achieved by bypassing the surplus flow of the propeller pump to replace the outlet throttling.
 
    Third, exports throttle
 
    This is one of the most common and inexpensive flow adjustment methods for low- and medium-specific speed pumps. Usually this method is also limited to low, medium speed than the number of pumps used. Partially closing any type of valve on the outlet line will increase the system head so that the system head curve will intersect the pipe pump head curve at a lower flow rate. The outlet throttling moves the operating point to a lower efficiency point and has a power loss at the throttle valve. This may be important for large-scale pump installations, and a higher investment adjustment method may be more economically attractive. Throttle to the dead point may cause fluid overheating in the pump, bypass can be used to maintain the necessary minimum flow, or a different adjustment means. This is very important for the pumps mentioned above for the treatment of hot or volatile liquids.
 
    Fourth, the intake throttling
 
    If there is sufficient NPSH available, then the suction line can be throttled by saving some power. Because the throttling of the outlet can cause the liquid to overheat or vaporize, the jet fuel pump often uses inlet throttling. At very low flow, the impeller of these pumps is only partially filled with liquid, so the input power and temperature rise is about throttle exhaust throttle full operation bit 1/30 condensate pump flow is usually used to control the depth of submergence 7, This is equivalent to the entrance throttling. Special designs can reduce the cavitation damage of these pumps to a negligible extent, but the energy levels also become quite low.
 
    Fifth, qi
 
    Air intake to the suction line of the pump is also a method of regulating the flow rate, this method can save some power compared with the output throttle. In general, it is not desirable to have air present in the delivered liquid and too much air always has the risk of the pump losing its priming head, so this method is rarely used in practice except in a few cases.
 
    If you want to buy pipeline pump can contact us  Weihu pump, our company is specialized in various types of pump manufacturing and computer control of water supply and drainage complete sets of equipment manufacturers to operate the pump-based products related to general motors, pumps and other related accessories.

Sewage pump should be how to go with the cable wires

When we use the sewage pump, sewage pump should be how to layout, also we need to pay attention to how to match the cable, the following is by Shanghai mine sewage pump manufacturer is simple to share with everyone, can be a reference for everyone.
First let's talk about sewage pump cable: when the installation of various types, will have the power and sewage pump machine distance is too long, need above the basis of the sewage pump accessory cable extension cable, so the size of all kinds of sewage pump power cable are decided according to the length of the cable.
Let's go ahead with sewage pump should be how to match the cable
First, to select the wiring sewage pump first according to the size of the cable to determine the length of the wiring, such as original pump configuration cable is 3 x10 cable with 100 square meters at this time should increase cable configuration 3 x16 square is appropriate. If use sewage pump itself power supply voltage is slightly lower than the voltage required sewage pump, and add the required length of cable configuration and longer, the operation of the sewage pump cable becomes larger, if the sewage pump working long hours for sewage pump motor is very bad, this kind of sewage pump under the condition of cable wiring should match YCW type or YC type rubber set soft cable, such as not cable advice to choose YCW dived into the water.
Second, if it is diving sewage pump have to according to the sewage pump conveying liquid medium to choose to match the line, such as transmission fluid is corrosive, so the outside of the cable rubber parts to choose stainless steel submersible pumps and corrosion submersible cable, or it will because the submersible cable corrosion and leakage of dangerous accidents.

Pipeline centrifugal pump in the use course of attention which points

When we use the pipeline centrifugal pump, how should we do it? Also need to pay attention to what the problem? The following by the weihu pump to share with you in the pipeline pump process we need to pay attention to those issues:
    First, pipeline centrifugal pump in the course of operation, the bearing temperature can not exceed the ambient temperature 3 ℃, high temperature shall not exceed 80 ℃.
    Second, unscrew the pipeline pump body of the water plug, irrigation diversion (or cited pulp).
    Third, start the pipeline centrifugal pump motor, when the normal operation of the pipeline pump, open the outlet pressure gauge and import vacuum pump, depending on the display of appropriate pressure, and gradually open the gate valve, and check the motor load.
    Fourth, to the pipeline centrifugal pump bearing body lubricating oil by adding bearings to observe the oil level should be at the center of the oil standard, the oil should be replaced or added.
    Fifth, close the centrifugal pump and pipeline centrifugal pump outlet pipe valve and outlet pressure gauge and import vacuum table. Jog the pipeline pump motor, see whether the motor steering is correct.
    Sixth, try to control the pipeline pump flow and head in the range indicated on the plate to ensure that the pipeline pump in the highest efficiency point of operation in order to obtain the greatest energy saving effect.
     Seventh, if there is abnormal sound pipe pump should immediately stop to check the cause.
    Eighth, the pipeline pump and pipeline from the main pump to stop using, first close the gate valve, pressure gauge, and then stop the motor.
    Ninth, check the pipeline pump and pipe and the junction with or without loosening. Turn the pipe pump by hand to see if the piping pump is flexible.
    Tenth, regularly check the pipeline pump sleeve wear, wear should be replaced after a large.
    Twelfth, pipeline centrifugal pump used in the winter season, after parking, the need to pump the lower part of the water plug screw open the media release the net to prevent cracking.
    Thirteenth, the pipeline pump long-term outage, need to open all the pipeline pump, dry water, the rotating parts and joints coated with grease installed, and properly preserved.
    Fourteenth, the pipeline pump in the first month of work, after 100 hours to replace the oil, after each 500 hours, oil change time.

Vertical pipeline pump use

ISG type pipeline centrifugal pump for conveying water and other physical and chemical properties similar to the use of water for industrial and urban water supply and drainage, high-rise building pressurized water, garden irrigation, fire booster and equipment, the use of temperature T: ≤80 ° C.
IRG (GRG) type hot water (high temperature) circulation pump is widely used in energy, metallurgy, chemical, textile, paper, hotel and other high-temperature hot water pressurized circulation and urban heating system circulation pump, IRG temperature T: ≤120 ° C, GRG Operating temperature T: ≤240 ° C.
IHG pipeline chemical pump for the transportation of non-solid particles, corrosive, viscosity similar to the liquid of water for petroleum, chemical, metallurgy, power, paper, food, pharmaceutical and synthetic fiber and other departments, the use of temperature T: 20 ° C to 120 ° C.
YG pipeline oil pump for the transportation of gasoline, diesel, kerosene and other petroleum products, the use of temperature T: -20 ° C-120 ° C.