2016年10月30日星期日

Vacuum pump exhaust oil how to solve?

Vacuum pump after use for a long time, if not for regular maintenance would be a big or small issues, such as exhaust oil, vent oil is only one: the main reasons why exhaust filters.
First, the causes of exhaust filter oil
1, exhaust filter fails, the oil and gas can't completely separate.
2, exhaust filter installation bad mouth o-ring seal.
3, exhaust filter installation does not reach the designated position. Shaft seal leakage, leakage problem is common.
Found that the shaft seal leakage due to abrasion, oil, must want to change the shaft sealing ring. Different pump types, different manufacturers design of shaft seal structure is not the same. According to the original design pattern with similar or identical seal change. Standard parts such as spring rubber ring wear air leakage is not serious, detachable go a few rounds of fastening wire spring loaded again can. Serious wear and tear shall be in accordance with the original diameter changing new sealing ring. O, j type and Jo type sealing ring, all have standard series, location should be paid attention to when assembling trued and pressure. Some of the rubber sealing ring can be homemade. Its inner diameter can be obtained by measuring the shaft and the shaft hole, size should be slightly smaller, there should be room for compaction thickness, easy to mount can lock itself.
Second, the vacuum pump daily maintenance methods
1, 3 to 6 months will be in a special vacuum pump oil, each pump in the factory when will indicate what is oil. You want to change original, don't mix,
2, about six months in a vent filters and in filter and treasure to vacuum pump oil.

Introduction to feed water pump running in the process of common failures and solutions

With the constant progress of the society, electric power and industrial development and people's life is closely related to the high grade energy, one of the growing demand for its people. Thermal power though right now the consumption of fossil fuels such as coal and pollution of the environment has a great influence, but according to the special national conditions of our country, coal is still the main mode of power supply, the proportion of the total installed capacity at about 70%. Thermal power plant is composed of boiler, steam turbine and generator three host and feed water pump, coal mill and other auxiliary equipment and control system. Feed water pump is a core system of thermal power plant boiler auxiliaries, its purpose is to continuously provide to boiler has the pressure, temperature and flow rate of water supply. Feed water pump is generally divided into two kinds of electric and steam, shanxi jincheng a 300 MW thermal power plant boiler supporting electric feed water pump. In the plant electric feed water pump, for example, this paper introduces the working process of the feed water pump, the common faults in the operation process and the corresponding solutions, in order to provide some reference for the general electric power staff.
Feed water pump is not only to provide sufficient pressure, temperature and flow rate of feed water boiler, but also provide reheater, superheater attemperator and reduction of warm water, so the safety and reliability of the feed water pump, a direct impact on the safety operation of boiler system and steam turbine generator set, serious when still can cause boiler water dry the occurrence of serious accidents, such as the higher the greater unit capacity and parameter, the importance of the feed water pump, the more prominent. [1]
Shanxi jincheng a thermal power plant 300 MW unit configuration is as follows: 50% capacity electric three main feed pump, two with one case. Models for DG600-240 - v (FK6D32); Type of cylinder core package, horizontal; Has six levels of impeller, motor models for YKS800-4 electric (Shanghai), feed water pump directly driven by motor through coupling, booster pump driven by motor directly, feed water pump and coupling, coupling and motor and motor and booster pump through the fold type shaft coupling.
Two common faults in the operation of feed water pump
Feed water pump can be stable operation of the safety and economy of boiler has a close relationship with large boiler unit generally configuration many sets of feed water pump, there are one or two electric feed water pump as backup. The power plant capacity 50% electric three main feed pump, 2 in one case, in the process of actual operation, the feed water pump fault has common motor overheating overheating [2], the pump body, pump body flow and system fault, such as vibration malfunction phenomenon, the possible reasons and solutions to see table 1.
3 in the operation of the feed water pump fault solution
3.1 the feed water pump troubleshooting
3.1.1 mechanical seal leakage, high temperature in the water injection pipe
As water injection pipe in air, check the mesh cleanliness, check whether the external cooling water is enough; If big is the collapse of the mechanical seal leakage, check whether the pump ring is installed backwards, cooler and the purity of the mesh, dynamic and static ring for wear.
3.1.2 bearing temperature is high
Check the lube oil cooler, increase the cooling water, adjust the oil hole plate, increase in traffic; Adjust the pressure relief valve, the oil pressure; The collapse of the bearing when necessary, check the bearing clearance.
3.2 the feed water pump booster pump troubleshooting
3.2.1 mechanical seal leakage
Spring force is not enough, loosen screw mechanical seal on the shaft sleeve, the sleeve to move about 1 ~ 2 mm, outside the pump to tighten the screw. If the big leakage, the need to strip inspection, replace if necessary.
3.2.2 the drive end bearing oil
Thrust bearing oil return is not the driving end plug holes on the bearing cover plate, often to the bearing chamber oil return, because of the large amount of oil return cause oil leakage. Reveal a plug hole plate, narrow small aperture.
3.2.3 booster pump shaft in small flow up
Double-suction volute pump in the small flow rate, the impeller out of the mouth room is easy to produce pressure fluctuations caused by axial channeling move, in the big traffic (about 300 t/h or above) or disappear completely, cold center, in accordance with requirements can reduce the booster pump shaft move.
3.2.4 cold installation to the center
Remove the upper cover of motor bearing, with a precise level 4 meters, on the shaft neck area, check the shaft back in internal carotid should be equal on both sides of the shaft, and in the opposite direction. If you need adjustable wedgeplug pad under the floor, to ensure our internal jugular back degrees equal on both sides of the axis, the reset bearing upper cover.
3.2.5 the axial position of motor rotor must be consistent with the center of the magnetic field of the motor
Runtime box body heat expansion, gear tooth force when rotating, bearing clearance, and the hydrodynamic lubricating oil can cause axis offset. Therefore in the pump set is cold find center, must be set in the horizontal, vertical, axial offset, the expected offset compensation when starting and running.
4 conclusion
Thermal power is made up of boiler, turbine and generator three host and feed water pump, coal mill, such as auxiliary coordination of unified whole, an equipment or system malfunction could affect the safety and reliability of the whole system, especially the feed water pump as the working medium for boiler equipment, is the core of the auxiliary boiler system, its role in the boiler system is self-evident. In the process of actual operation, because of the feed water pump working environment is bad. Frequently, all kinds of feed water pump failure, the staff must be regularly for feed water pump of power plants for maintenance, found problems in a timely manner, to ensure the safe operation of boiler feed water pump and system.

The working principle of the vertical self-priming pump

Self-priming pump is southern commonly used a pump. Principle is to use the water velocity of flow momentum, drives the pump impeller impeller pumping water into the river. Thrown into the river to the pump pumping, but must be water, or a place to have head.
Self-priming pump and centrifugal pump is different in general. Centrifugal pump, before work, pump body and feed line must be tank filled with water into a vacuum, when the fast rotating impeller blade promote water quickly spin, spin the water under the action of centrifugal force, fly away from the impeller, pump in the water is thrown, the center of the impeller part form the vacuum area. Water in the original water at atmospheric pressure (or hydraulic) through the pipe network pressure under the action of the feed water pipe. So circulates, can achieve continuous pumping.
Self-priming pump is not need irrigation water diversion, this is the origin of self-priming pump.
Self-priming pump self-priming principle: as the pump shell's special design. Its high sealing performance than general centrifugal pump, and motor to halt the water in the pump housing will not automatically after emptying, motor drive the turbine at high speed, quickly make form a negative pressure (vacuum) inside the pump. After using atmospheric pressure pumping water to the pump shell, centrifugal head again. So, self-priming pump suction, no more than an atmospheric pressure, about 11 m.
Scope of application of self-priming pump
1, suitable for urban environmental protection, construction, fire control, chemical, pharmaceutical, dyes, and dyeing, brewing, electric power, electroplating, paper making, washing of industrial mines, cooling of equipment, etc.
2, with a swing arm sprayer, the water can rush into the air, a small drips to spray, is a good tool for farm, nursery, garden, garden.
3, suitable Yu Qingshui, water, chemical liquid medium with acid, alkalinity and with general mushy slurry (medium viscosity < 100 mm pearl, solid content of 30%).
4, and can be matched with pressure filter of any model and specifications, send paste to filter machine supporting the ideal pump for filter.

The choice of drainage pumps and requirements

Building use drainage pumps are submersible sewage pump, liquid discharge pump, vertical sewage pump and horizontal sewage pump, etc. Because within the building area is lesser, general displacement is not big, give priority to use diving sewage pump and drainage pump liquid discharge pumps, including submerged sewage pump is in commonly used in important places; Vertical and horizontal sewage pumps pump set isolation requirements, since the irrigation water, and take up a certain field, so the less use in the building.
Drainage pump flow should be according to the second life drainage design flow of the selected; When a displacement adjustment, drainage maximum hours flow selected according to life. Fire elevator collecting basin drainage pump flow within not less than 10 l/s.
Drainage pump lift according to hoisting height, piping loss calculation is determined, then add some free head. Free head should be 0.02 ~ 0.03 MPa. Drainage pump suction pipe and outlet pipe flow velocity should not be less than 0.7 m/s, and should not be more than 2.0 m/s.
Public buildings should be in each life drain collecting basin as a unit set up a backup pump, at ordinary times should be interactive operation. Basement, equipment room, garage flushing the drainage of the ground, such as when there are more than two and two drainage pumps don't pump equipment. When collecting basin can't set accident drainage pipe, water pump should be uninterrupted power supply; When can close drainage inlet pipe, not for uninterruptible power supply, but should be set up alarm device.
As ascension with larger impurities of sewage, waste water, the different set inside the pool diving sewage pump outlet pipe should not be combined discharge; When raising the waste water, according to actual situation consider different collection pool diving sewage pump outlet pipe combined discharge.
Two or more than two Shared a water pump outlet pipe, shall be installed on each pump outlet pipe valve and check valve. Single pump drainage could produce flow backward, should set the check valve. Don't allow pressure drainage clearance and architecture in gravity drainage consolidation.
When diving sewage pump ascending containing large pieces of debris, appropriate of diving sewage pump with a crushing device; When ascending contains more fiber content of sewage, appropriate USES thoroughfare diving sewage pump.
When diving sewage pump motor power is greater than or equal to 7.5 kW or outlet pipe diameter greater than or equal to the DN100, water pump fixed automatic coupling device can be used; When diving sewage pump motor power is less than 7.5 kW or outlet diameter less than DN100, can install a hose mobile. Wastewater collection pool with diving sewage pump drainage, should set the pump fixed automatic coupling device, convenient pump maintenance.
Drainage pump should be able to automatic start-stop and field manual start-stop. Pumps can run in parallel alternating more, also can be segmented in operation.

Adjustment methods of centrifugal pump and the energy consumption analysis

Through the analysis of the characteristic curves of centrifugal pump and pipeline system of centrifugal pump flow control main ways: export valve adjustment, pump variable speed adjustment and pump series, in parallel to adjust. Export was analyzed by using the characteristic curves of regulating valve and pump speed regulating energy loss in two ways, and has carried on the contrast, points out that the centrifugal pump with variable speed regulating flow than with export flow adjusting valve can better save energy consumption, and energy saving efficiency and the size of the flow changes. In practical application, you should pay attention to the range of speed regulation, can better use centrifugal pump variable speed control.
Centrifugal pump is widely used in chemical industry system of a kind of fluid machinery. It has to adapt to the wide scope of performance (including flow, pressure head and adapted to the nature of the medium), small volume, simple structure, easy operation, low operation cost, a lot of advantage. Usually, the selected centrifugal pump flow rate and pressure head may and asked for in line, or change due to the production task, technological requirements, at this time are required to adjust the discharge pump, essence is to change the working point of centrifugal pump. Centrifugal pump working point is by the characteristic curve of pump and piping system joint decision characteristic curve, therefore, any change of characteristic curve can achieve the purpose of flow control. At present, the centrifugal pump flow control ways are regulating valve, variable speed control and pump control and, series adjustment, etc. Due to all sorts of the principle of adjustment for different, in addition to have their own advantages and disadvantages, the energy loss is different also, in order to seek the best, the minimum energy consumption, the most energy-efficient way of flow control, must fully understand the flow of a centrifugal pump adjustment methods and the relationship between the energy consumption.
1 the main pump flow control
1.1 change the pipeline characteristic curve
Change the simplest method is to use centrifugal pump pump discharge valve to control the opening, the essence of which is the location of the change of pipeline characteristic curve to change the working point of the pump.
1.2 change the centrifugal pump characteristic curve
According to the proportion law and the law of cutting, change the pump rotation speed, the pump structure (such as the method of cutting impeller diameter, etc.) both methods could change characteristic curve of centrifugal pump, so as to achieve the purpose of flow adjustment, change the pressure head at the same time). But for the pump work, has changed the pump structure method is not very convenient, and because change the structure of the pump, reduces the versatility of the pump, even though it at some point adjustment convenient traffic economy [1], and rarely used in production. Just how changes in centrifugal pump flow of speed adjusting method. From figure 1, when change the pump speed adjusting flow rate decreased from Q1 to Q2, the pump speed (or motor speed) decreased from n1 to n2, speed under n2 pump characteristic curve of Q - H and the pipeline characteristic curve He = H0 + G1Qe2 (line curve does not change) to point A3 (Q2, H3), point A3 for the new speed adjusting flow after working point. The adjustment method of adjustment effect, quick, safe and reliable, can prolong the service life of the pump, save electricity, reduce speed running also can effectively reduce the NPSH of centrifugal pump NPSHr, away from the pump cavitation area, reduce the possibility of centrifugal pump cavitation occurred [2]. The disadvantage is that change the pump speed by variable frequency technology are needed to change the prime mover (usually) of the motor speed, principle of complex, investment is bigger, and the flow adjustment range is small.
1.3 pump series, and even the adjustment way
When a single centrifugal pump can't meet the delivery task, can use of centrifugal pump in parallel or in series operation. With two sets of the same type of centrifugal pump in parallel, although the head changed little, but increased the total transportation flow, the total efficiency of the pump in parallel with a single pump efficiency is the same; Centrifugal pump series when the total pressure head, flow rate change is not big, the total efficiency of the pump with single pump efficiency is the same.
Energy consumption analysis of two pumps under different adjustment modes
Analysis of energy consumption under different adjustment modes, the article in view of the present regulating valve and pump variable speed regulation is widely adopted by two types of regulation. Due to centrifugal pump and, series aims to improve the pressure head or flow, in the field of chemical industry use is not much, analyze its energy consumption can be combined with figure 2, the method is basically the same.

Pump selection principles and steps

Pump is a kind of a lot of wide range of general-purpose machinery and equipment, it is widely used in petroleum, chemical, electric power, metallurgy, mining, choose ship, light industry, agriculture, civil and defense departments, occupies an important position in national economy. According to 79 statistics, pump output reached 1.256 million units in China. Pump power consumption accounted for more than 21% of the national power consumption. So vigorously reduce pump energy consumption, to save energy use is of great significance.
Designed and developed in recent years, we have pump industry a lot of high efficiency and energy saving products, such as IHF, CQB, such as the FSB, UHB models of pump products, to reduce the energy consumption of the pump plays a positive role. But now in various fields of national economy, due to the unreasonable type selection, many of the running status of pump in the unreasonable operation efficiency is low, waste a lot of energy. And due to the unreasonable selection of pump, it was impossible to use, or use the maintenance cost increases, the economic benefit is low. Therefore, reasonable choose pump is of great significance to save energy.
So-called reasonable selected pump, is to consider investment and operation cost of pump unit and pumping stations comprehensive technical and economic indexes, such as make it conform to the principle of economy, safety and applicable. In particular, has the following several aspects:
Must meet the requirements of the use of flow and head, requiring the pump running work time points (device characteristic curves with the pump performance curve intersection) often remain within the range of efficient operation, save power and not easy attaint parts.
The choice of the pump should not only small volume, light weight, cheap, and has good characteristics and higher efficiency.
Has good resistance to cavitation performance, this can not only reduce the pump room of the excavation depth, and the water pump cavitation occurs, smooth operation, long service life.
Built according to the selected pump pumping station, the project less investment, low operating cost.
The second section selection steps
A basic data, list:
1, the characteristics of the medium: the name of the medium, specific gravity, viscosity, corrosive, toxic, etc.
In 2, medium contained in the body of particle diameter, how much content.
3, medium temperature (℃)
4, need traffic
General industrial pump can be ignored in the process of pipeline system leakage, but affected by the change of flow must be considered. Agricultural use, if is adopted, open channel water pump must also consider leakage and evaporation.
5, pressure: suction tank pressure, water pressure, the pressure drop of pipeline system (head losses).
6, pipeline system data (diameter, length, kinds and number of pipeline accessories, vacuum pressure to the pool geometry level, etc.).
Should also make the device characteristic curve, if necessary.
Decorate in the design line, should pay attention to the following items:
A, reasonable choose pipe diameter, pipe diameter is big, under the same flow rate, liquid flow velocity is small, small resistance loss, but the price is high, the pipe diameter is small, can lead to resistance losses increase sharply, increase the selected pump lift, installed with power increasing, the cost and operation cost are increased. So from the perspective of technical and economic comprehensive consideration.
B, discharge pipe and pipe joints should be considered are the biggest pressure.
C, pipeline layout should decorate straight pipe as far as possible, try to reduce the attachment and try to narrow the pipe length, pipe must turn, elbow bend radius should be 3 ~ 5 times the diameter of the pipe, as much as possible Angle is greater than 90 ℃.
D, the discharge side of the pump must be installed with the valve (ball valve or valve, etc.) and check valve. Used to adjust the point of pump, valve check valve when the fluid flow reversal can prevent the pump inversion, and makes the pump to avoid water hammer blow. (when the liquid flow back, will produce a great reverse pressure, make the pump damage)

2016年10月28日星期五

Ten reasons and solutions of Pump lift not enough

Weihu pump industry in the past for the user maintenance encountered problem in the process of water pump is not enough, one of them is water pump lift weihu pump industry pump maintenance technicians here today to simple about the cause and the solution, the pump head is not a lack of enough pump head might mechanical electrical system may also have reasons.
Pump lift is not the cause and the solution
One of the reasons for pump head is not enough, liquid contains excessive amounts of air or gas. Solution: reduce the liquid temperature out of gas.
Pump head is not enough for another, the speed is too low. weihu pump industry solution: check whether the voltage is in the range of rated voltage, check whether the motor running normally.
The cause of the pump head is not enough 3, motor turn to right. weihu pump industry solution: because the power of fire against money and zero line, changing a line, the problem is human reason, is generally not easy to appear.
Four of the cause of the pump head is not enough, the total head above water pump design head. Solution: replace the head higher levels of the water pump.
Five of the cause of the pump head is not enough, the concentration of the liquid and the design value. Solution: replace conform to the requirements of the pump.
Six of the cause of the pump head is not enough, the operation flow rate is far lower than the minimum flow. weihu pump industry solution: replace conform to the requirements of the pump.
Seven of the cause of the pump head is not enough, abrasion and ring. Solution: replace the qualified new wear ring.
Eight of the cause of the pump head is not enough, the damage of impeller. Solution: replace the qualified new impeller.
Nine of the cause of the pump head is not enough, resulting in pump head gasket damage caused by internal leak is not enough. Solution: replace the qualified new gasket.
Ten of the cause of the pump head is not enough, sundries mixed in the pump, the impeller and port blocked. Solution: remove the pump clear clutter.