2016年10月27日星期四

The use of submersible pump and maintenance

1. Start:
(1) the following 11 kw pumps allow direct start, 13 kw or more pumps should be equipped with step-down starting cabinet, to protect the safe operation of electric pump.
(2) in order to avoid the electric pump rotor moment and reduce the starting load, electric pump start-up time should be the outlet valve stroke off to 3/4. (leave a quarter of the air gap. In order to put gas) to start after the water slowly open, to pump under control in the appropriate position.
(3) started running after the start, should strengthen the supervision and the observed water level change, ensure pumps within the scope of the condition of operation, can be put into operation after pumps running smoothly.
(4) pumps in operation for the first time after five hours, stop quickly measuring thermal insulation resistance, its value is not less than 0.5 M Ω, can continue to use.
2. Stop the pump:
Before electric pump stop, to prevent the backflow of water, at the same time of cut off the power to close the valve, restart time every 20 minutes.
3. The operation and maintenance:
(1) pumps should be to work in the design point, the axial force is moderate, pump efficiency is highest, the most economical and reliable. (2) pumps every work 8 hours to full check, each instrument for change, whether the circuit nodes fever, voice is normal. Whether the normal working current is greater than the motor nameplate rating.
4. One of the following circumstances, should immediately stop the pump:
(1) the working current of the pump suddenly above the motor rated current
(2) the water yield is not normal, gap water, sediment concentration increased
(3) the motor insulation resistance is lower than 0.5 ohms
(4) has obvious noise vibration of unit
(5) power grid voltage is not enough, less than 5% of the rated voltage
(6) the fuse burned a phase
(7) delivery road damage
5. Matters needing attention in operation and maintenance:
(1) check that the current voltage and discharge pressure every day, every 2 weeks testing dynamic water level, and make records.
(2) every four weeks to check the insulation resistance of motor and make records.
(3) use of start times to reduce as far as possible.
(4) pumps if well under discontinuous after use, should boot up once a week, and run the 5-10 minutes, to prevent pumps for corrosion can't start.
6. Electric pump storage and handling:
Store to put a net electric pump motor cavity effusion, dry surface, shaft coupling head to besmear antirust oil, erected in place. (in order to prevent the rotor deformation) in a dry, no chemical corrosive articles, normal temperature, winter storage of not less than 3 ℃ temperature.

How to use the safe and efficient mining multistage pump?

Mine multistage pumps suitable for mines, factories and urban water supply and drainage, used to transport water without solid particles or liquid, physical and chemical properties similar to Yu Qingshui scope and area is very broad. Devices commonly used shaft seal packing seal, according to user needs can also adopt mechanical seal. Equipment operation direction from the motor end looked pump is clockwise. How to use the safe and efficient mining multistage pump? This is used at the beginning of many users often ask the question. First of all, we from the pump to introduce oneself: pump sealing is very good - water section, middle/water was still in combination with surface molybdenum disulfide seals, also has the gasket seal paper, tear open after reshipment seal must use raw materials, to prevent water from entering the bearings on both ends, "O" type of synthetic and hydrosphere sealing. Rotational part and fixed part of the pump by the sealing ring, between the guide vane and packing. Packing chamber zhongtong into a certain pressure of water, water seal and cooling effect.
In the process of running often should pay attention to the following:
1. Observe the ammeter, listen to sounds, determine whether normal operation;
2. Observe whether motor overload, it is strictly prohibited to motor current operation;
3. Observe the shaft seal leakage situation, and adjustment, to adjust the injected water, sometimes with continuous dropwise is preferred;
4. Check the oil ring sliding bearing rotation. The temperature of the rolling bearing should be less than 75 ℃;
5. Check the clearance between the two coupling, when in need to replace the balancing device;
6. Observe the equalizer pipe of the water temperature, when the water temperature rise quickly, should stop pump check whether the balance pipe is blocked;
7. Observe the pressure gauge, vacuum gauge, when both gage pressure is abnormal, should be timely find out the reason;
8. Observe the water level to prevent light;
9. When the water level low note two shaft seal will inhale into the pump;
10. Pay attention to the operation condition of the pump, cooling water conditions.
Should not have to pay attention to is multistage pump under the condition of the outlet valve full close for a long time; Work shouldn't hump in the performance curve. Should ensure feed line during the operation of the valve is fully open on the road. The starter valve closing time shoulds not be long. No more than 2 ~ 3 min, otherwise, cause vaporization temperature, can damage the pump.

2016年10月26日星期三

The centrifugal pump the causes of common faults and processing methods

In the feed water system, water pump in a running condition, often used for a variety of fault make water pump can't work normally. The centrifugal water pump common fault, causes and handling methods:
1. The pump is not water
(1) when the water pump suction pipe for down slope inside of air, gas, and has set up a water pump can't continuous suction caused by the water pump is not water. When there is a down slope, the slope should be adjusted, and timely troubleshooting the air pump body and suction tube.
(2) suction bottom valve is lax or damaged, the suction pipe under water, or bottom valve and water intake were choked up with silt sundry, to close the bottom valve is lax. When after confirm the fault should be timely clean up dirt, bottom valve, the damage should be replaced.
(3) the bottom valve submerged depth can also cause the pump is not enough water, should increase the depth of the suction pipe dipped in the water.
(4) tank (tank) water level is too low will make the water pump is not in the water, at this time should check whether the water into the water, the water pressure in the system is woefully inadequate, ball valves, liquid level control valve malfunction. Find problems should timely adjust the filling time (e.g., use of slack when water filling water at night), the inlet valve repair or replacement failure.
2. The submerged depth of the water pump water yield decrease except check suction, suction pipe down slope to save gas and other reasons, still need to check whether the water pump impeller sealing ring is damaged, and the timely replacement.
3. The water pump bearing overheating when the pump is running, the bearing temperature rise should not be more than 60 ℃, when bearing the lack of oil or water pump and motor shaft different heart, bearing gap is too small, too tightly on the packing, all can cause bearing overheating. At this point, we should adjust the concentricity, refueling, adjust the packing gland firmness.
4. The pump running vibration and noise is too big.
Pump concentricity deviation is too large will produce larger vibration, the second should check if the anchor bolts, foundation bolts tightened without loose. To require strict control of noise and vibration of buildings should increase vibration or vibration isolator.
When the depth of the suction pipe is too large, water when the water level is too low, will cause the water pump cavitation phenomenon and increase the pump noise.

The basic construction of self-priming centrifugal pump and the inlet piping requirements

The basic construction of self-priming centrifugal pump is composed of six parts, respectively, impeller, pump body, pump shaft, bearing, seal ring, stuffing box.
1, is the core part of self-priming centrifugal pump impeller, strength higher than that of its speed, on the impeller blades and play a major role, the impeller through static balancing experiments before assembly. Impeller on the inside and outside for smooth surface to reduce friction loss of water.
2, the pump body also calls the pump shell, it is the body of the pump. Support fixed effect, and connected to install bearing bracket.
3, the role of pump shaft is connected by coupling and motor, the torque of the motor to the impeller, so it is a major part of the mechanical energy transfer.
4, bearing is set on the pump shaft support components of pump shaft, which has two kinds of rolling bearing and sliding bearing. Rolling bearing use butter as a lubricant oil is generally appropriate for two-thirds to three-quarters of the volume too much will be fever, too little and there was a noise and fever! Sliding bearing is using a transparent oil as lubricant, go to the oil level line. Too much oil leak to the pump shaft and floating base, too little bearing overheating and burn out cause an accident! Bearing has the highest temperature in the process of pump working in 85 degrees generally run around 60 degrees, if the high will find reason (if there are impurities, oil is black, whether water) and processed in a timely manner!
5, sealing ring, also known as minus leakage ring. Import and pump impeller shell gap between in the cause of high water in the pump by means of this clearance flow to the low pressure area, affect the water yield of pump, efficiency! Clearance starts to cause the impeller and pump casing friction wear. In order to increase the flow resistance reducing internal leakage and delay the service life of the impeller and the pump shell, the pump casing and impeller around the foreign aid junction with sealing ring, sealing gap in between 0.25 ~ 1.10 mm is advisable.
6, stuffing box is mainly composed of filler, seal ring, packing, packing gland, water tubes. The role of the stuffing box is mainly in order to close the gap between pump casing and pump shaft, don't let the flow within the pump does not flow outside to not let outside air into the pump. Always keeping the vacuum inside the pump! When the pump shaft and be about to rely on water seal packing friction heat to hold water to the water seal circle packing cooling! Keep the pump running. So in the process of pump run Tours of inspection to check the stuffing box is paying special attention to! Running about 600 hours will be carried out on the packing replacement.

Pipeline centrifugal pump performance curve and the eight use erroneous zone

There are three main pipeline centrifugal pump performance curve curve: flow - head curve, traffic - power curve, traffic - efficiency curve.
A, flow - head characteristic curve
It is the basic of centrifugal pump performance curve. Specific speed is less than 80 of the centrifugal pump has the characteristics of rising and falling (curved) under both raised among, both sides, said hump performance curve. Specific speed centrifugal pump has between 80 ~ 150 flat performance curve. Than revolutions in the more than 150 centrifugal pump has a steep fall in the performance curve. Generally said, when the traffic hours, head high, with the increase of traffic head will gradually decline.
B, flow - power curve
Shaft power is increases with flow rate, when the flow rate Q = 0, the corresponding shaft power is not equal to zero, and to a certain value (about 60% of the earth's normal operation). The main power consumption on the mechanical loss. Is full of water in the pump at this time, if the long run, will lead to pump temperature rising, the pump shell, bearing will be fever, serious when can make the pump body thermal deformation, we called "stuffy head", the head of the maximum, when gradually open the discharge valve, the flow rate will gradually increase, shaft power also slowly increase.
C, flow - efficiency curve
Xiangshan head shape, its curve when the flow rate is zero, efficiency is also equal to zero, with the increase of flow rate, efficiency is also increased gradually, but efficiency has decreased after increased to a certain value, there is a high efficiency, near the highest efficiency point, efficiency is high, the region known as the high efficiency area
Eight pipeline centrifugal pump use erroneous zone
A, pipeline centrifugal pump pipe way of matching
Some pipeline centrifugal pump users think it can improve the actual lift, but the actual head loss = total head ~ head of pump. When the water pump model is determined, the total head is certain; Head loss mainly comes from the pipeline resistance, the smaller the diameter is obviously the greater the resistance, and therefore the greater the loss of head, so reduce the pipe diameter, the actual head of pump instead of increased, it will reduce, to lower the pump efficiency. By the same token, when small diameter water pump with large water pumping, also won't erode the real value of the pump head, may because of the line in order to reduce the loss of the head with the decrease of the resistance, the actual lift have improved. There is also a machinist think small diameter water pump with large water pumping, will greatly increase the motor load, after they think diameter increases, the water in the outlet pipe of pump impeller pressure is big, so will greatly increase the motor load. Little imagine, the size of the liquid pressure only associated with head high and low, and have nothing to do with the size of the pipe sectional area. As long as the head must be, water pump impeller size remains the same, no matter how big pipe diameter, pressure effect on the impeller is certain. Just pipe diameter increases, the flow resistance will decrease, and make the flow rate increases, power consumption are increasing. But as long as within the scope of rated head, no matter how to increase the pump diameter can be normal work, and also can reduce line losses, improve the efficiency of the pump.
Second, high lift water pump used for low-lift pumping
Some pipeline centrifugal pump users think the lower water head, the smaller the motor load. Under this false understanding of misleading when water pump of choose and buy, often the selection of the pump head high. In fact for the centrifugal pump, when the water pump model is determined, the size of the consumed power is proportional to the actual flow pump. And pump flow will decrease with the increase of the head, and the higher the head, the smaller the flow, and the smaller power consumption. Conversely, the lower the head, flow rate, the greater the consumption of power. Therefore, in order to prevent the motor overload, general requirements the actual water use head of the pump shall not be less than 60% of the labeling head. So when the high-lift pump used for low head pumping motor easy to overload and fever, serious when can burning motor. If emergency use, must be in the outlet pipe with a gate valve is used to adjust the water yield (or use the content such as wood wall small outlet), to reduce the flow, to prevent the motor overload. Pay attention to the motor temperature rise, if discover motor overheating, should be timely down outlet flow or turn it off. It is also easy to produce misunderstanding, some machinist think blocking outlet, forced to reduce traffic, can increase the motor load. In fact just the opposite, formal power centrifugal pump irrigation and drainage units are fitted on the outlet pipe of gate valve, in order to reduce the unit startup motor load, should be closed gate, after waiting for motor start and gradually open the gate. 

Deep well submersible pump installation and use of the method

1. Deep well submersible pump acceptance: user acceptance check carefully to the logistics company delivery cable sheath have damaged. Water pump with and without fracture.
2. Handling, loading and unloading car need to be careful, so as not to damage the concentricity of the unit or touch broken cable insulation.
3. A complete set of unit under well before the inspection steps: a. open mesh, even with all pry bar shaft should be flexible rotation, B put add fresh water, the electric pump shaft connected cable joint, with water immersion, joint rock joint to ground resistance measurement (single joint insulation resistance) of water value is not less than 500 ohms. C. put using suitable container to pump the water pump set of export with detergent water, at the same time point to move a little bit about the motor start button to see the pump steering, time shall not be more than 2 seconds, completes the sequential markers.
4. When pump fission transportation field assembly steps: a. before installation will put the motor to the vertical, open porosity and water injection hole, pay attention to must open the both water block, add fresh water to water plugging and water plugging is tightened, observe the motor if there is leakage phenomenon, if there is leakage phenomenon must not well, the reason may is the transport process of knock against, should contact the agent or manufacturer's talk things over solve, until not leak (10 ~ 15 minutes). And then shake test motor insulation resistance, the value of no less than 50 ohms. B. bandage cable joint, wrapped after try the steering motor, motor turns to the direction of the arrow marked on the pump are consistent, and sequential markers.
5. Submersible deep-well pump inspection when fission
A. on the pump shell is removed to show the top of the impeller, b. flexible c. rotating impeller by hand to see if the pump shaft direction pull the seven total amount up to observe the impeller impeller (QJ pump commonly 4 to 6 mm) d. install connecting shaft and motor into one to make the motor shaft head and pump shaft head of tight no cracks are allowed. E. jumped up and down the impeller clearance, should be in the middle of the amount of total channeling location (allowable deviation plus or minus 0.5 mm). F. when the deviation is greater than 0.5 mm in adjustment gasket to the middle position in hand rotating impeller should be flexible. G. then even the axis is the top wire holes, tighten the top wire installed on the shell. H. again even with all pry bar should be flexible rotation for a week and put shaft device. Then pretend to filter and convenient slot on the box.
6. Under the deep well submersible pump well, the well before the rope hanging a in units of the same length logs or steel pipe (diameter) unit is equal to the largest diameter test tube well is upright. In order to avoid the well stuck units.
(especially new well first pump, mine do not need this step).
7. The cable tie, cable to use insulation cable tie binding to raise water pipes, don't use metal wire.
8. Control of the unit and start: control equipment selection. Motor power by 1.2-1.4 = power control cabinet. Control cabinet to be lack of phase, overload, over current short circuit protection, etc. Started well after the installation of commissioning, startup time according to the difference of motor power, master between 10 to 25 seconds, high-power motor startup time should be relatively long, check whether the current overload, whether the three phase current balance and recorded. As the basis of warranty and feedback manufacturer.
9. Overload, short circuit, over current, lack of phase, debugging sensitivity: this step is very important, please installation personnel serious debugging.

How to increase the self-priming pump self-priming capacity?

Household self-priming pump is self-priming ability, can make the water pump in the high places in the low level of the liquid or water suction pump cavity through the impeller flung in a high speed liquid, to handle liquid and promotion purposes. Household self-priming pump the service life of the product is unqualified or too long, sometimes self-priming ability to drop, to reach the purpose we need, but self-priming pump because it is the different way of imbibition, can be divided into the mixed type self-priming pump, internal mixing type self-priming pump and powered by the pump itself water vacuum pump self-priming pump structure in the form.
Here are several ways to improve the service life of self-priming pump, self-priming ability:
The first way is also the most simple way: self-priming sewage pump set vacuum pump in the pump suction pipe on the road, before starting the pump, vacuum pump to start, first make the pump suction tube is full of water, first ensure the pump automatically, rapid start. This way of absorbing perfect automatic control system is needed to guarantee the normal work.
The second method relative to the following is also belongs to the relatively simple: self-priming pump to reduce the feed water pipe bend, drop height and horizontal intervals.
The third method is a bit of trouble, but also is very useful: self-priming pump set before the pump suction tank. This way needs to be on the water pump suction pipe to set up a water tank, pump before the first run, the tank should be artificial filled with water, the first run after resting, as a result of absorbing water tank inlet pipe height above the tube surface height, although the water level below the height of the tank water in tank, tank of water will not flow back, into the pool, so the water tank can store a certain amount of water, and as a result of the water tank outlet pipe (i.e., the water pump suction pipe) height below the tube surface height, so can ensure the pump suction pipe is full of water, water pump to run again, the water in the pitcher is draining pump, tank pressure, on the pool of water at atmospheric pressure under the action of supplement to the water tank, by absorbing water tank inside the pool.
Finally a way to self-priming sewage pump suction pipe end suction bottom valve installation. Suction bottom valve is actually a check valve, it ensure that water can only be by the pool in suction pipe and can't go back, so if the suction tube is full of water, although the pump axis elevation above the pool water level, but because of the suction bottom valve, the suction tube of water will not flow into the pool, can make the suction tube is full of water all the time, ensure the pump automatically, rapid start.