2016年11月6日星期日

Precautions for Vacuum Pump Selection

Vacuum pump prices, rotary vane vacuum pump, vacuum pump selection
1, the ultimate pressure of the vacuum pump should meet the working pressure of the process. It is usually chosen that the pump's ultimate pressure is less than about one order of magnitude of the process requirement.
2, each pump has a certain working pressure range, therefore, the pump operating point should be selected within this range, and not allow it to work outside the long hours of work pressure.
3, the vacuum pump at its working pressure, should be able to drain away the vacuum equipment in the process of generating all the gas volume.
4, select the vacuum unit:
   (1) When using a pump can not meet the pumping and vacuum requirements, the need for several pumps together, complement each other to meet the process requirements.
   (2) Some vacuum pumps can not work at atmospheric pressure, the need for pre-vacuum; some vacuum pump outlet pressure is lower than atmospheric pressure, the need for the former pump, it is necessary to combine the use of the pump. The combination of the vacuum pump, we call the vacuum pump unit, which can make the vacuum system to get a better vacuum and displacement. We should choose the correct combination of vacuum pump, because different vacuum pump on the gas extraction requirements are different requirements, for example: in general, Roots - rotary unit is not suitable for containing more condensable gas system.
5. When you choose the oil seal pump, you should first understand whether your vacuum system is oil pollution requirements. If the rigorous requirements of oil-free equipment, should choose a variety of oil-free pumps, such as: water ring pump, cryogenic pumps. If the requirements are not strict, you can choose a pump, coupled with a number of anti-pollution measures, such as cold trap, block oil trap, baffle, but also to achieve clean vacuum requirements.
6, to understand the gas composition was pumped, the gas contains no condensable steam, with or without particulate dust, corrosive and so on. When selecting a vacuum pump, it is necessary to know the gas composition and to select the pump for the pumped gas. If the gas contains steam, particles, and corrosive gases, should be considered in the pump inlet pipe on the installation of auxiliary equipment, such as condensers, dust and so on.
7, when the choice of oil seal vacuum pump, to consider the vacuum pump discharged from the oil vapor (soot) on the impact of the environment. If the environment does not allow pollution, should choose oil-free vacuum pump, or the oil vapor to the outside.
8, the vibration of the vacuum pump work on the process and whether the impact of the environment, if the process does not allow, should choose no vibration of the pump or take anti-vibration measures.
9, the price of vacuum pumps, operation and maintenance costs.
   Once we have taken into account the various circumstances before we can finalize a solution for your adaptation:
   (1) the minimum investment costs.
   (2) the minimum production operating costs.
   (3) the first two cases a reasonable and even distribution of feasible option

Maintenance of Vertical Centrifugal Pump

In-service maintenance and repair
      1, the inlet pipe must be highly sealed, can not leak, leak;
      2, prohibit GDL vertical centrifugal pump in the cavitation state long-term operation;
      3, prohibits GDL-type vertical centrifugal pump running in high-flow conditions, the motor over-current long-term operation;
      4, regular inspection GDL vertical centrifugal pump running the motor current value, as far as possible within the scope of the pump design to run;
      5, GDL-type vertical centrifugal pump should be in the operation of care, in order to avoid accidents;
      6, GDL-type vertical centrifugal pump should run every 500 hours to refuel the bearing;
      7, GDL-type vertical centrifugal pump for long-term operation, due to mechanical wear and tear, so that the unit noise and vibration increases, should stop inspection, the need to replace the vulnerable parts and bearings, unit overhaul period is generally one year.
      Mechanical seal maintenance and repair
      1, mechanical seal lubricating fluid should be clean without solid particles;
      2, is strictly prohibited mechanical seal dry grinding in the case of work;
      3, start before the plate pump (motor) a few laps, so as to avoid a sudden start mechanical seal fracture damage.

2016年11月3日星期四

Checking Method of No - load Operation of Motor for Deep Well Pump

When using the vertical deep well submersible pump, how to carry on the idling operation examination to the deep well pump electric motor. The following by our deep well pump manufacturers in Shanghai weihu and we simply talk about the inspection method.
    First, check the oil, the correct amount of oil should be in the middle of the oil marked the middle position. Oil shortage should be appropriate to add 10 mechanical oil, oil should be appropriate to put too much oil.
    Second, check the wiring is completed, you can electrify for no-load operation. If the motor does not turn should immediately stop, and the power cord of any two for another then start; if the motor has not yet started, you should carefully check the power supply system is not good, whether there is two-phase power supply or power is not connected.
    Third, the motor starts to complete the speed to stabilize, the motor should be parking for mechanical inspection. The mechanical connection parts such as the emergence of loose, falling or collision and other phenomena, should be adjusted and repaired.
    Fourth, the motor no-load operation should be continued for 2-3 hours, running in time to check for irregularities or sound appears. After the end of the operation check whether the bearing overheating situation. If there are abnormal circumstances, should be adjusted and repaired immediately.

Shanghai pump manufacturers to talk about when the pump overhaul need to pay attention to what

Pump overhaul cycle is based on the operation and technical conditions to determine the unit, "Pump Station Technical Management" provides that the pump overhaul cycle: the main pump for 3-5 years or 2500-15000 hours of operation, the main motor 3-8 years or 3000-20000 hours of operation. And may advance or postpone overhaul according to the situation.
    In determining the pump overhaul cycle and workload, we should pay attention to several aspects, the following by the Chinese pump manufacturers say as follows:
     First, if there is no special requirements, try to avoid disassembly technology can be good parts and bodies.
     Second, should try to extend the maintenance cycle. According to the wear and tear parts, similar equipment running tests, equipment performance indicators to determine the pump overhaul cycle, regardless of the wear of certain parts. Therefore, the overhaul should be planned in order to ensure the normal operation of the unit.
     Third, as far as possible to avoid the demolition of all components of the unit body, especially the precision, finish, with the requirements of high components, institutions.

Shanghai pump manufacturers to talk about the structure and cooling form of centrifugal pump

In the use of centrifugal pumps, we will reduce the centrifugal pump sealing temperature to improve the efficiency and service life of centrifugal pumps, the following by our Shanghai pump manufacturers to say,
    First of all, we say that the centrifugal pump seal structure
    1, single-ended centrifugal pump seal: the use of injection-type washing, washing liquid is about 100 ℃ by the second line of wax oil, the pressure than the sealed cavity high 0.05-0.15Mpa. Gland outside the use of hot water (soft water) for rapid cooling. One cycle (ten months) can be used in general.
    2, centrifugal pump metal bellows seal: compact, easy to install, in the case of the same auxiliary system, the life of 2-3 times the normal seal.
    3, centrifugal pump double-end mechanical seal: the cycle of washing, plus external cooling, life is single-sided 1.5-2 times.
    4, centrifugal pump friction pair selection hard to hard (YG6 / YG8, SiC / SiC, etc.), high viscosity, with a small amount of solid particles of the medium or crystallization of the media, have a good effect.
    Then we talk about the centrifugal pump cooling form.
    1, domestic centrifugal pump in the sealed chamber around the cooling water jacket set to cool the water, can seal the chamber temperature is reduced to 200-250 ℃.
    2, on the single-ended seal, the use of injection-type cleaning, from the outside lead clean, the temperature of about 100 ℃ wax oil (usually without diesel, because diesel is finished), both reduce the temperature and improve the working environment is effective Approach.
    3, gland outside the use of quench water; in addition to lower temperatures, but also to prevent clogging sewer.

Submersible pump repair and maintenance

Submersible pumps on a regular basis on the submersible pump and its control system for comprehensive maintenance, at least l times a year to do a comprehensive preventive maintenance, including:
    (1) when the vibration of the sound and voltage and current with or without abnormalities; stainless steel multi-level deep well submersible pump
    (2) start the device is working properly;
    (3) whether over-temperature water leakage alarm;
    (4) whether the multi-protection established by the measurement and control is frequent;
    (5) the main cable and control cables are aging and cracking;
    (6) whether the main contactor sticky oxidation or burr;
    (7) thermal relay settings are correct;
    (8) whether the winding insulation signs of aging;
    (9) Insulation resistance to ground is too low;
    (10) three-phase winding resistance is balanced;
    (11) the stator rotor to ask whether there are sweeping or scratches;
    (12) control system level gauge is accurate;
    (13) whether the upper and lower limit output is normal and reliable;
    (14) whether the float action is reliable;
    (15) whether the temperature detection components aging malfunction;
    (16) whether the oil emulsification;
    (17) mechanical seals are intact;
    (18) bearing with or without wear;
    (19) impeller wear or cavitation;
    (20) whether the shaft rust deformation or wear;
    (21) whether the motor inside and outside fastening screw loose;
    (22) cooling jacket and circulating water pipes in the presence of debris;
    (23) whether the pump and the surrounding sediment deposition or blockage.
    In the preventive maintenance and submersible pump operation process, should be correctly distinguish between over-temperature alarm, the alarm is really over-temperature or aging components of the malfunction. In the case of component aging, the signal will only access the alarm signal, not to directly participate in control, to reduce the frequent start of the submersible pump.
    Frequently Asked Questions in Maintenance Work Submersible pumps are immersed in water for long periods of use, causing the aging of the main cable skin to crack. Water penetrates the cable directly into the submersible pump. Therefore, it is necessary to inspect the cables regularly, Cracks, cleaning the surface of the cable after cleaning, waterproof tape can be used for waterproofing, but be careful to soak a few hours after the insulation check with a shake table to meet the requirements before put into operation. Replace the main cable with an insubstantial or non-repairable value. Because the main cable is a watertight connector with a dedicated cable, the replacement price is more expensive, so the process can be used to save costs of bonding.
    In the daily inspection, in addition to full operation control, test instruments, but also to display their subjective active role, as Chinese medicine practitioners to diagnose the disease "look, smell, ask, cut" as abnormal pump abnormalities. "Look" is to see, take a look at the instructions of various ministries pressure, flow, temperature, current, voltage is normal, the pump components have deformation, discoloration, change and whether the leak, with or without plugging; Smell, smell the unusual taste, liquid hydrocarbons, gasoline, benzene and other smells of leakage, equipment, paint, rubber and other insulation burnt paste paste taste; "ask" is to listen, listen to the voice of the rolling sector, with or without Abnormal sound, such as water hammer, friction sound, percussion, vortex sound, breaking sound, etc .; "cut" is to touch, touch whether overheating, vibration and so on. Only in this way the role of the operator, in a variety of test instruments, instruments of assistance, can the daily inspection well, early detection of anomalies, preventive measures.

How to reduce the energy consumption of submersible pumps?

How to reduce the energy consumption of submersible pumps?
We all know that in the summer is the peak of water, so the pump on a good maintenance of some, began to use, then in the course of how we like to reduce the energy consumption of wells with submersible pumps?
Here we will explain in detail for you some:
First, the pump surface and pressure water chamber (also known as volute) on the surface rust.
Surface corrosion bumps will reduce the pump water 7% -8%; maintenance only steel brush and iron sandpaper or grinding wheel smooth, you can make it in the work of fuel consumption or power consumption reduced by 9% -14%.
Second, the seal ring gap increases
According to the test when the impeller radius in the direction of the gap increased by 4 mm, the pump water will be reduced by 10%; maintenance only with organic adhesive plus asbestos back to the factory-defined gap, you can make the pump fuel consumption at work or electricity Consumption reduced by 10% -12%.
Third, the pressure chamber and impeller axis does not coincide
When the pressure chamber and the impeller axis deviation of 2 mm or more than 2 degrees, the pump water will be reduced by 5% -6%; maintenance only careful measurement, carefully identify the axis coincidence of the location of the installation of a solid, you can make the pump Reduced oil or power consumption by 6% to 7% during operation.