Submersible pump failure phenomenon and elimination method

1, check the motor. To see if the motor has to check motor starting not starting to eliminate circuit fault can be  whether motor wiring connection correct check whether electric pump reverse electric pump reversal switch power supply cord.
2, check the line. Look after the road if there is a wall, rupture, filter water blockage. If the pipeline rupture should be repair welding or in tube unclog fault can be ruled out.
3, check the pump casing seal check whether the impeller is damaged. Elimination method  change the new seal, impeller.
Second, the motor can't start with hum
1, check whether a motor circuit breakers check whether the voltage is the voltage is too low. After repair, adjust voltage normal fault can be ruled out.
2, check whether there is foreign body inside the impeller, the bearing damage to remove foreign bodies or replace the bearing.
Three, current is too large, ammeter pointer swing
1, when buying a new pump for shaft bending, bearing different heart immediately get back the sales department or factory.
2, check whether the thrust bearing is badly worn impeller with ring friction marks. Elimination method replace the thrust bearing and thrust plate of the impeller rotates with sealing ring friction can no longer.
3, check the shaft and the shaft when relative rotation is flexible rotation is not flexible, should replace or repair the bearings.
4, dynamic water level dropped to below inlet. Traffic shall be reduced or in the well.
Four, severe vibration unit operation
1, check whether the connecting bolt is loose bolts should be tightened.
2, a motor rotor imbalance, imbalance of water pump impeller, motor or the pump shaft bending failure should be sent after the factory for processing.